Модуль аналогового входу VIPA SM331 331-1KF01

Відкласти Порівняти
Характеристики

Гарантия   —   4 місяці

Стан   —   Вживаний

6332 грн./шт:
У наявності
Order no. 331-1KF01 Type SM 331 General information Note - Features 8 inputs 13 bit Voltage, current Resistance Resistance thermometer SPEED-Bus - Current consumption/power loss Current consumption from backplane bus 255 mA Power loss 1.3 W Technical data analog inputs Number of inputs 8 Cable length, shielded 50 m Rated load voltage - Current consumption from load voltage L+ (without load) - Voltage inputs Min. input resistance (voltage range) 100 kOhm Input voltage ranges -50 mV ... +50 mV -500 mV ... +500 mV -1 V ... +1 V -5 V ... +5 V 0 V ... +10 V -10 V ... +10 V +1 V ... +5 V Operational limit of voltage ranges +/-0.5% ... +/-0.6% Operational limit of voltage ranges with SFU - Basic error limit voltage ranges +/-0.3% ... +/-0.4% Basic error limit voltage ranges with SFU - Destruction limit current - Current inputs Max. input resistance (current range) 100 Ohm Input current ranges -20 mA ... +20 mA 0 mA ... +20 mA +4 mA ... +20 mA Operational limit of current ranges +/-0.5% Operational limit of current ranges with SFU - Radical error limit current ranges with SFU +/-0.3% Radical error limit current ranges with SFU - Destruction limit current inputs (electrical current) - Destruction limit current inputs (voltage) - Resistance inputs Resistance ranges 0 ... 600 Ohm 0 ... 6000 Ohm www.vipa.com © by VIPA GmbH, Ohmstr. 4, 91074 Herzogenaurach, Germany All data with reservation and subject to change. Publish date: 13.05.2015 Page 2/3 Operational limit of resistor ranges +/-0.5% Operational limit of resistor ranges with SFU - Basic error limit +/-0.3% Basic error limit with SFU - Destruction limit resistance inputs - Resistance thermometer inputs Resistance thermometer ranges Pt100 Ni100 Ni1000 Operational limit of resistance thermometer ranges +/-1K ... +/-1.2K Operational limit of resistance thermometer ranges with SFU - Basic error limit thermoresistor ranges +/-0.8K Basic error limit thermoresistor ranges with SFU - Destruction limit resistance thermometer inputs - Thermocouple inputs - Thermocouple ranges - Operational limit of thermocouple ranges - Operational limit of thermocouple ranges with SFU - Basic error limit thermoelement ranges - Basic error limit thermoelement ranges with SFU - Destruction limit thermocouple inputs - Programmable temperature compensation - External temperature compensation - Internal temperature compensation - Internal temperature compensation - Technical unit of temperature measurement - Resolution in bit 13 Measurement principle Sigma-Delta Basic conversion time 61 ms/51 ms / channel Noise suppression for frequency 50 Hz/60 Hz Initial data size 16 Byte Status information, alarms, diagnostics Status display none Interrupts no Process alarm no Diagnostic interrupt no Diagnostic functions no Diagnostics information read-out none Supply voltage display none Group error display none Channel error display none Isolation Between channels - Between channels of groups to - Between channels and backplane bus Between channels and power supply - Max. potential difference between circuits - Max. potential difference between inputs (Ucm) DC 2 V www.vipa.com © by VIPA GmbH, Ohmstr. 4, 91074 Herzogenaurach, Germany All data with reservation and subject to change. Publish date: 13.05.2015 Page 3/3 Max. potential difference between Mana and Mintern (Uiso) - Max. potential difference between inputs and Mana (Ucm) - Max. potential difference between inputs and Mintern (Uiso) DC 75 V/ AC 60 V Max. potential difference between Mintern and outputs - Insulation tested with DC 500 V Datasizes Input bytes 16 Output bytes 0 Parameter bytes 21 Diagnostic bytes 0

Швидке замовлення

Ваше им'я*
Ваш телефон*

Зворотний дзвінок