Specifi cations
|
EXE 602 E
|
EXE 660 B
|
|
Input
|
»
11 µAPP
|
|
Electrical
Connection
|
M23
fl ange socket (female) 9-pin
|
|
Cable
length
|
†
30 m for IEncoder † 120 mA
|
|
Interpolation1)
|
Without, 5-fold
|
25-fold,
50-fold, 100-fold, 200-fold, 400-fold
|
|
Input
frequency1) for interpolation
Without
5-fold
25-fold
50-fold
100-fold
200-fold
400-fold
|
Nominal
values2)
|
|
50
kHz
|
–
|
|
25
kHz
|
–
|
|
–
|
50
kHz
|
50
kHz
|
25
kHz
|
12.5
kHz
|
–
|
50
kHz
|
25
kHz
|
12.5
kHz
|
6.25
kHz
|
–
|
25
kHz
|
12.5
kHz
|
6.25
kHz
|
3.12
kHz
|
–
|
12.5
kHz
|
6.25
kHz
|
3.12
kHz
|
1.56
kHz
|
–
|
6.25 kHz
|
3.12
kHz
|
1.56
kHz
|
0.78
kHz
|
Output
|
«
TTL (unclocked)
|
«
TTL (clocked)
|
|
Electrical
connection
|
M23
fl ange socket (male) 12-pin
|
|
Cable
length
|
†
100 m (¥ † 50 m)
|
|
Edge
separation a
|
‡
2.500 µs
|
‡
0.500 µs
|
‡
0.075 µs
|
‡
0.175 µs
|
‡
0.370 µs
|
‡
0.760 µs
|
Reference
mark signal1)
|
Pulse
width 90° elec. or ungated (only
when without interpolation) or 270°
elec.
|
|
Fault
indication1)
|
through
fault detection signal ¥ or, in
addition, Ua1/Ua2 high impedance
|
|
Power supply
|
5
V ± 5%
|
|
Current consumption3)
|
†
90 mA
|
†
120 mA
|
|
Operating temperature
Storage temperature
|
0
°C to 70 °C
–30
°C to 80 °C
|
|
Vibration 50 to 2000
Hz
Shock 11 ms
|
† 10 m/s2
†
300 m/s2
|
|
Protection
|
IP
65
|
|